Transcribed Medical Transcription Sample Reports and Examples
Transcribed Medical Transcription Sample Reports and Examples
|

View this sample in Blog format on MedicalTranscriptionSamples.com

Sample Type / Medical Specialty: Surgery
Sample Name: Cardiac Catheterization - 9

Description: Cardiac catheterization and coronary intervention report.
(Medical Transcription Sample Report)

EXAM: Cardiac catheterization and coronary intervention report.

PROCEDURES:
1. Left heart catheterization, coronary angiography, left ventriculography.
2. PTCA/Endeavor stent, proximal LAD.

INDICATIONS: Acute anterior ST-elevation MI.

ACCESS: Right femoral artery 6-French.

MEDICATIONS:
1. IV Valium.
2. IV Benadryl.
3. Subcutaneous lidocaine.
4. IV heparin.
5. IV ReoPro.
6. Intracoronary nitroglycerin.

ESTIMATED BLOOD LOSS: 10 mL.

CONTRAST: 185 mL.

COMPLICATIONS: None.

PROCEDURE: The patient was brought to the cardiac catheterization laboratory with acute ST-elevation MI and EKG. She was prepped and draped in the usual sterile fashion. The right femoral region was infiltrated with subcutaneous lidocaine, adequate anesthesia was obtained. The right femoral artery was entered with _______ modified Seldinger technique and a J wire was passed. The needle was exchanged for 6 French sheath. The wire was removed. The sheath was washed with sterile saline. Following this, the left coronary was attempted to be cannulated with an XP catheter, however, the catheter folded on itself and could not reach the left main, this was removed. A second 6-French JL4 guiding catheter was then used to cannulate the left main and initial guiding shots demonstrated occlusion of the proximal LAD. The patient had an ACT check, received additional IV heparin and IV ReoPro. The lesion was crossed with 0.014 BMW wire and redilated with a 2.5 x 20-mm balloon at nominal pressures. The balloon was deflated and angiography demonstrated establishment of flow. Following this, the lesion was stented with a 2.5 x 18-mm Endeavor stent at 10 atmospheres. The balloon was deflated, reinflated at 12 atmospheres, deflated and removed. Final angiography demonstrated excellent clinical result. Additional angiography was performed with a wire out. Following this, the wire and the catheter was removed. Following this, the right coronary was selectively cannulated with diagnostic catheter and angiographic views were obtained in multiple views. This catheter was removed. The pigtail catheter was placed in the left ventricle and left ventriculography was performed with pullback pressures across the aortic valve. At the end of procedure, wires and catheter were removed. Right femoral angiography was performed and a right femoral Angio-Seal kit was deployed at the right femoral arteriotomy site. There was no hematoma. Peripheral pulses _______ procedure. The patient tolerated the procedure well. Symptoms of chest pain resolved at the end of the procedure with no complications.

RESULTS:
1. Coronary angiography.
A. Left main free of obstruction.
B. LAD, subtotal proximal stenosis.
C. Circumflex large vessel with three large obtuse marginal branches. No high-grade obstruction, evidence of minimal plaquing.
D. Right coronary 70% mid vessel stenosis and 50% mid to distal stenosis before giving rise to a right dominant posterior lateral and posterior descending artery.
2. Left ventriculogram. Left ventricular ejection fraction estimated at 45% to 50%. There was an akinetic apical wall.
3. Hemodynamics. Aortic pressure 145/109, left ventricular pressure 147/13, left ventricular end-diastolic pressure 34 mmHg.

IMPRESSION:
1. Acute ST-elevation myocardial infarction, culprit lesion, left anterior descending occlusion.
2. Two-vessel coronary disease.
3. Mild-to-moderate impaired LV systolic function.
4. Successful stent left anterior descending, 100% occlusion, 0% residual stenosis.

PLAN: Overnight observation in ICU. Start aspirin, Plavix, beta-blocker and ACE inhibitor. Check serial cardiac enzymes. Further recommendations to follow. Check fasting lipid panel, in addition add a statin. Further recommendations to follow.

Keywords: surgery, coronary intervention, heart catheterization, coronary angiography, ventriculography, /endeavor stent, ptca, st elevation, cardiac catheterization, catheterization, angiography, coronary,
NOTE: These transcribed medical transcription sample reports and examples are provided by various users and are for reference purpose only. MTHelpLine does not certify accuracy and quality of sample reports. These transcribed medical transcription sample reports may include some uncommon or unusual formats; this would be due to the preference of the dictating physician. All names and dates have been changed (or removed) to keep confidentiality. Any resemblance of any type of name or date or place or anything else to real world is purely incidental.
Home | MedicalTranscriptionSamples | MT911 | MTDictionary | MTSetup | MTHelpLine
Sitemap | Tell a Friend | Contact Us | Disclaimer

Transcribed Medical Transcription Sample Reports and Examples